Continuous and bimonthly publication
ISSN (on-line): 1806-3756

Licença Creative Commons
10242
Views
Back to summary
Open Access Peer-Reviewed
Educação Continuada: Metodologia Científica

Understanding diagnostic tests. Part 1.

Entendendo os testes diagnósticos. Parte 1.

Juliana Carvalho Ferreira1,2, Cecilia Maria Patino1,3

DOI: http://dx.doi.org/10.1590/S1806-37562017000000330

PRACTICAL SCENARIO



Investigators studied the diagnostic accuracy of serum procalcitonin levels to diagnose parapneumonic pleural effusions (PPE) and differentiate it from other causes of pleural effusions. They found that procalcitonin (with a cut-off value of 0.195 ng/mL) had a sensitivity of 83% and a specificity of 80% to diagnose PPE and accurately diagnosed individuals with PPE.(1)



USING DIAGNOSTIC TESTS IN CLINICAL PRACTICE



Clinicians are frequently faced with the challenge of diagnosing a disease based on diagnostic test results. Most diagnostic tests used in clinical practice, however, are not perfect and produce false positive results (the test is positive, but the patient does not have the disease) and false negative results (the test is negative, but the patient has the disease). Therefore, learning to interpret the properties of diagnostic tests is a critical competency for clinicians and researchers. In this article, we discuss sensitivity and specificity. In the forthcoming parts, we will discuss positive and negative predictive values, and receiver operating characteristic (ROC) curves.



Sensitivity and specificity are important measures of a diagnostic test because they give us an idea of how well a new diagnostic test performs when compared with an existing gold standard test. Sensitivity is defined as the proportion of subjects with the disease who have a positive test. In the example in Table 1, true positives (n = 39) divided by the total number of subjects with disease (n = 47) results in 83%. Specificity is defined as the proportion of subjects without the disease who have a negative test. In the example, true negatives (n = 81) divided by total number of subjects without the disease (n = 101) results in 80%.

 






When a new diagnostic test is evaluated, the investigator sets a cut-off point which defines whether the test is positive or negative, and there is always a trade-off between sensitivity and specificity. In our example, if the cut-off point for a positive procalcitonin test was decreased from 0.195 ng/mL to 0.095 ng/mL, it might detect more cases of PPE, decreasing the false negative rate and increasing sensitivity, but the test would also be positive in more subjects without PPE, increasing the false positive rate and decreasing specificity. This trade-off between sensitivity and specificity for several possible cut-off points can be used to plot a ROC curve and describe the overall test performance in discriminating between presence and absence of the disease; we can also use sensitivity and specificity to calculate likelihood ratios, as we will see later in this series.



Sensitivity and specificity are useful measures to evaluate the performance of a diagnostic test but are not very helpful for personalized clinical decision making.(2) When a clinician is facing a patient with a positive test result, the most important question is: what is the probability that, given that the test is positive, the patient has the disease? The sensitivity of the test does not tell us that; it tells us the probability of a positive test, given that the patient has the disease. We will address more relevant clinical measures of diagnosis in part 2 of this series.



REFERENCES



1. He C, Wang B, Li D, Xu H, Shen Y. Performance of procalcitonin in diagnosing parapneumonic pleural effusions: A clinical study and meta-analysis. Medicine (Baltimore). 2017;96(33):e7829. https://doi.org/10.1097/MD.0000000000007829

2. Altman DG, Bland M. Diagnostic tests. 1: Sensitivity and specificity. BMJ. 1994;308(6943):1552. https://doi.org/10.1136/bmj.308.6943.1552