Continuous and bimonthly publication
ISSN (on-line): 1806-3756

Licença Creative Commons
8393
Views
Back to summary
Open Access Peer-Reviewed
Artigo Original

Physicochemical properties of human tracheobronchial sputum maintained at room temperature

O muco traqueobrônquico humano mantido em temperatura ambiente e suas propriedades físico-químicas

Renata Claudia Zanchet, Gilvânia Feijó, Ada Clarice Gastaldi, José Roberto Jardim

ABSTRACT

Objective: To evaluate the effect that maintaining tracheobronchial sputum at room temperature has on the analysis of ciliary transport and cough, as well as on the contact angle. Methods: Hyaline sputum was collected from 30 individuals without pulmonary diseases, and purulent sputum was collected from patients with bronchiectasis. The samples were analyzed immediately after collection and again after 24 h. Results: After 24 h at room temperature, the purulent sputum presented an increase in cough-induced dislodgment (96 ± 50 vs. 118 ± 61 mm) and a decrease in the contact angle (32 ± 6 vs. 27 ± 6 degrees) (p < 0.05). For the hyaline sputum, there were no alterations in the parameters analyzed. Conclusion:  Hyaline tracheobronchial sputum can be stored in room temperature for 24 h without presenting alterations in ciliary transport or contact angle. However, purulent sputum should not be stored at room temperature for many hours, since ciliary transport and contact angle might be altered as a result.

Keywords: Temperature; Sputum; Cough; Mucociliary clearance

RESUMO

Objetivo: Verificar a influência da permanência em temperatura ambiente na análise da transportabilidade por ação ciliar e por tosse e do ângulo de contato do muco traqueobrônquico. Métodos: Foi coletado muco hialino de 30 indivíduos sem doença pulmonar, e purulento de vinte pacientes com bronquiectasia. As amostras foram analisadas logo após a coleta e novamente após 24 h. Resultados: Para o muco purulento, após 24 h em temperatura ambiente, houve aumento no deslocamento por tosse (96 ± 50 vs. 118 ± 61 mm) e diminuição do ângulo de contato (32 ± 6 vs. 27 ± 6 graus) (p < 0,05). Para o muco hialino não houve alterações nas medidas analisadas. Conclusão: O muco traqueobrônquico hialino pode ser armazenado em temperatura ambiente por 24 h sem que haja alterações em sua transportabilidade por ação ciliar ou em seu ângulo de contato. Por outro lado, o muco purulento não deve permanecer em temperatura ambiente por muitas h para que não se altere seu ângulo de contato e sua transportabilidade por tosse.

Palavras-chave: Temperatura ambiente; Muco; Tosse; Depuração mucociliar

Introduction

Human tracheobronchial sputum is commonly studied in vitro(1) with the objective of evaluating the physiology and physiopathology of the respiratory tract(2) as well as the response to different therapeutic measures.(3)

The in vitro study of human sputum consists of evaluating the physicochemical properties of the sputum, such as its capacity to be transported through ciliary activity and cough, which is also known as transportability. The chemical properties, which express, in detail, the composition of the sputum, as well as the physical properties, such as viscoelasticity, adhesiveness, spinnability and wetability, influence in vitro and in vivo sputum transport.(4)

The methods of studying in vitro transport have the advantage of determining the transportability of the sputum, irrespective of existing alterations in the ciliated epithelium of the airways or in the capacity to generate adequate flow for efficacious coughing.(4) Those methods are very important, principally in terms of the scientific validation of bronchial hygiene techniques or the use of mucolytic drugs, both of which have the ultimate objective of eliciting the expectoration of sputum.

With the increasing interest in studies on tracheobronchial sputum, the detailing of technical factors that may interfere with the analyses of the sample properties is essential. It is known that sputum should be analyzed immediately after collection(5) or frozen for later analysis at temperatures of -20 °C,(6) -70 °C(1) or -80 °C.(6) However, until the sputum sample is frozen or analyzed, it remains at room temperature. That period should be short in duration but, when that is not possible, what are the consequences of sputum remaining at room temperature for prolonged periods? Do samples of different macroscopic aspects present different behaviors in relation to their physical properties?

There are reports of sputum analysis carried out 60 min,(5) 120 min,(7,8) 180 min(9) and 240 min(10) after the collection. Some authors have observed that storing sputum at 37 °C for 60 min,(9) or at room temperature for 24 h,(7) decreases its viscosity. However, these authors utilized the sputum samples of only one patient and did not clarify the degree of purulence of the samples.

The objective of the present study was to determine the effect that maintaining sputum at room temperature for 24 h has on the contact angle and transportability of tracheobronchial mucoid and purulent sputum.

Methods

The sputum of individuals without pulmonary diseases, considered mucoid, was collected from 21 men and 9 women with a mean age of 37 ± 21 years who had been submitted to general anesthesia for extrathoracic surgery. Those individuals had no history of pulmonary diseases or any signs of viral or bacterial respiratory tract infection within the preceding six weeks.

Purulent sputum was collected from 20 patients (12 men and 8 women) with bronchiectasis not resulting from cystic fibrosis. The mean age was 52 ± 10 years. The bronchiectasis was diagnosed through clinical testing, chest X-rays or computed tomography scans of the chest. Yellowish or greenish sputum samples were considered purulent, with the number of leukocytes per field being = 24 and the number of epithelial cells per field being = 10.(11) The number of cells in ten microscopic fields at a magnification of ×1000 was observed.

This study was approved by the research ethics committees at the Triangle University Center and the Federal University of Sao Paulo. All of the patients gave written informed consent.

The mucoid sputum was obtained by scraping the inner surface of the endotracheal tube, after extubation, of patients submitted to extrathoracic surgery under general anesthesia.(12) The purulent sputum was obtained from phlegm, thereby avoiding salivary contamination. The sputum was collected in, at most, three coughing sessions without the prior use of any muco-active medication or physical therapy technique.

Immediately after collection, the samples were stored in plastic containers submersed in mineral oil, which was utilized to avoid the dehydration of the sputum.(13) Prior to the analysis of the sputum samples, the mineral oil was removed by immersing the samples in petroleum ether.

The temperature of the laboratory where the samples were stored was maintained at approximately 20 °C, although the relative humidity was not regulated.One sputum sample from each individual was analyzed at 1-2 h after collection and again after 24 h at room temperature. The mucoid sputum, due to the small quantity collected, was evaluated only in terms of the ciliary transportability and contact angle.

The purulent sputum was studied in terms of the contact angle, as well as in terms of the ciliary and cough transportability.The contact angle of the sputum was measured in accordance with the method described by Girod et al.,(4) immediately after the sample had been deposited on a slide. Five measurements of the contact angle were taken, and the mean value was calculated.

Ciliary transportability was evaluated using the frog palate method.(6,14) The isolated palate of Rana catesbeiana frogs was used. The time required for the sample to move 6 mm in the frog palate was measured five times per sample. The velocity of the sputum was expressed as relative velocity, which consists of the mean velocity of the sputum test divided by the mean velocity of frog mucus, which was used as a control.

The cough transportability was studied with a simulated cough machine developed by King et al.,(15) adapted by Gastaldi et al.(6) and having the following characteristics: oxygen pressure of 4.2 kgf/cm2; solenoid valve opening time of one second; cylindrical acrylic tube of 4 mm in internal diameter and 30 cm in length. For each sputum sample, five measurements of cough-induced displacement were taken, and the mean value was calculated.

The results were analyzed using the Wilcoxon test, and a level of 5% was considered statistically significant. Despite the fact that nonparametric statistics were used, we opted to describe the data using means and standard deviations in order to facilitate the comprehension of the results.

Results

In this study, it was noted that there was no statistically significant difference between the samples of mucoid sputum analyzed at 1-2 h after the collection and those analyzed after 24 h at room temperature, both with respect to ciliary transportability (0.87 ± 0.19 vs. 0.9 ± 0.2, respectively) and contact angle (26 ± 3 vs. 23 ± 3 degrees, respectively) (Figure 1).





In relation to the purulent sputum, there was no statistically significant difference with respect to ciliary transportability (0.72 ± 0.24 vs. 0.69 ± 0.19, respectively), although there was an increase in the displacement in the simulated cough machine (96 ± 50 vs. 118 ± 61 mm, respectively; p < 0.05) and a decrease in the contact angle values (32 ± 6 vs. 27 ±
6 degrees, respectively) (Figure 2).






The statistical calculations were conducted for only 19 of the 20 samples studied, since one of them became liquefied 24 h after collection, precluding its analysis. In addition, all of the samples of purulent sputum presented a decrease in their consistency, i.e. they became more fluid, thereby making their handling difficult.

Discussion

In the present study, there were no statistically significant differences in the ciliary transportability or contact angle of the mucoid sputum after 24 h at room temperature. We believe that the lack of alteration of the sputum properties was due to the small number of inflammatory cells, bacteria and enzymes present in the sputum of individuals without pulmonary diseases,(16) in addition to the fact that the method of collection results in little contamination by saliva.

However, the purulent sputum presented alterations not only in ciliary transportability; there was a statistically significant decrease in the contact angle values and an increase in displacement in the simulated cough machine at 24 h after collection (p < 0.005). This indicates a degenerative effect on the structure of the sputum, which was confirmed by the decrease in its consistency. Some authors(17) have associated the liquefaction of sputum stored at room temperature with enzymatic activity. Confirming this precept, other authors(18) observed that alpha-naphthyl acetate esterase, present in the alveolar macrophages of sputum, bronchial secretions and alveolar lavage, still presented some function after 72 h, despite having presented a progressive loss of activity after 24 h at room temperature.

It is known that the sputum of bronchiectasis patients contains a large number of enzymes, principally neutrophilic proteases.(19) Therefore, although the enzymatic activity of the samples of the present study was not evaluated, it is believed that the alterations of the purulent sputum may have occurred due to the action of enzymes released by the lysis of leukocytes and bacteria in the mucin secretory pathway. One example of an enzyme released in sputum by bacteria is the metalloproteinase elastase derived from Pseudomonas aeruginosa.(20)

In conclusion, tracheobronchial mucoid sputum can be stored at room temperature for 24 h without any alteration in its ciliary transportability or contact angle. Purulent tracheobronchial sputum, however, should not remain at room temperature for many hours, since it undergoes alterations in its physical properties and can become liquefied. However, since no intermediate analyses between 2 h and 24 h after collection were carried out, future studies are warranted in order to determine the maximum time that purulent sputum can remain at room temperature, thereby allowing alterations in its structure and, consequently, transportability to be avoided.

References

1. Albertini-Yagi CS, Oliveira RC, Vieira JE, Negri EM, de Oliveira LR, Saldiva PH, et al. Sputum induction as a research tool for the study of human respiratory mucus. Respir Physiol Neurobiol. 2005;145(1):101-10.

2. Deneuville E, Perrot-Minot C, Pennaforte F, Roussey M, Zahm JM, Clavel C, et al. Revisited physicochemical and transport properties of respiratory mucus in genotyped cystic fibrosis patients. Am J Respir Crit Care Med. 1997;156(1):166-72.

3. Valente AM, Gastaldi AC, Cravo SL, Afonso JL, Sologuren MJJ, Guimarães RC. The effect of two techniques on the characteristics and transport of sputum in patients with bronchiectasis. A pilot study. Physiotherapy. 2004;90(2):158-64.

4. Girod S, Zahm JM, Plotkowski C, Beck G, Puchelle E. Role of the physicochemical properties of mucus in the protection of the respiratory epithelium. Eur Respir J. 1992;5(4):477-87.

5. Zayas JG, Man GC, King M. Tracheal mucus rheology in patients undergoing diagnostic bronchoscopy. Interrelations with smoking and cancer. Am Rev Respir Dis. 1990;141(5 Pt 1):1107-13.

6. Gastaldi AC, Jardim, King M. The influence of temperature and length of time of storage of frog mucus samples. Biorheology. 2000;37(3):203-11.

7. Denton R. Bronchial obstruction in cystic fibrosis: rheological factors. Pediatrics. 1960;25:611-20.

8. Puchelle E, Tournier JM, Zahm JM, Sadoul P. Rheology of sputum collected by a simple technique limiting salivary contamination. J Lab Clin Med. 1984;103(3):347-53.

9. Sturgess J, Palfrey AJ, Reid L. Rheological properties of sputum. Rheol Acta. 1971;10(1):36-43.

10. Charman J, Reid L. Sputum viscosity in chronic bronchitis, bronchiectasis, asthma and cystic fibrosis. Biorheology. 1972;9(3):185-99.

11. Wong LK, Barry AL, Horgan SM. Comparason of six different criteria for judging the acceptability of sputum specimens. J Clin Microbiol. 1982;16(4):627-31.

12. Rubin BK, Ramirez O, Zayas JG, Finegan B, King M. Collection and analysis of respiratory mucus from subjects without lung disease. Am Rev Respir Dis. 1990;141(4 Pt 1):1040-3.

13. King M, Macklem PT. Rheological properties of microliter quantities of normal muçus. J Appl Physiol. 1977;42(6):797-802.

14. Sade J, Eliezer N, Silberberg A, Nevo AC. The role of mucus in transport by cilia. Am Rev Respir Dis. 1970;102(1):48-52.

15. King M, Brock G, Lundell C. Clearance of mucus by simulated cough. J Appl Physiol. 1985; 58(6):1776-82.

16. Lundgren JD. Mucus production in the lower airways: a review of experimental studies. Dan Med Bull. 1992;39(4):289-303.

17. Blasi A, Olivieri D. Conteúdo enzimático das secreções. In: Blasi A, Olivieri D. Hipersecreção brônquica: fisiopatologia, clínica, terapia. São Paulo: Andrei; 1982. p. 33-47.

18. Wehle K, Pfitzer P. Nonspecific esterase activity of human alveolar macrophages in routine cytology. Acta Cytol. 1988;32(2):153-8.

19. Fahy JV, Schuster A, Ueki I, Boushey HA, Nadel JA. Mucus hypersecretion in bronchiectasis: the role of neutrophil proteases. Am Rev Resp Dis. 1992;146(6):1430-3.

20. Mandl I, Keller S, Cohen B. Microbial elastases: A comparative study. Proc Soc Exp Biol Med. 1962;109:923-5.
_____________________________________________________________________________________________
* Study conducted in the Mucus Laboratory of the Universidade Federal de São Paulo (UNIFESP, Federal University of São Paulo) - São Paulo (SP) Brazil.
1. PhD in Molecular Pathology from the Universidade de Brasília (UnB, University of Brasília) - Brasília (DF) Brazil.
2. PhD in Health Sciences from the Universidade Católica de Brasília (UCB, Catholic University of Brasília) - Brasília (DF) Brazil.
3. PhD in Rehabilitation from the Universidade de São Paulo (USP, University of São Paulo) at Ribeirão Preto School of Medicine - Ribeirão Preto (SP) Brazil.
4. Tenured Professor at the Universidade Federal de São Paulo (UNIFESP, Federal University of São Paulo) - São Paulo (SP) Brazil.
Correspondence to: Renata Claudia Zanchet. Universidade Católica de Brasília, Núcleo de Reabilitação Cardiopulmonar. Sala A004, QS 07, lote 01, Águas Claras, CEP 71966-700, Taguatinga, DF, Brasil. Phone 55 61 3356-9005. E-mail: renatazanchet@ucb.br
Submitted: 4 October 2005. Accepted, after review: 17 May 2006.


Indexes

Development by:

© All rights reserved 2024 - Jornal Brasileiro de Pneumologia